Conventional Detectors


 
Z610-1 Conventional Ionization Smoke Detector, PS1221.3

Designed to provide an early response to fast burning fires, the Z610-1 ionization detector features reliable sensing of both visible and invisible products of combustion, for a range of conventional fire alarm applications. The detectors advanced design and proven response make it effective in risk areas where materials such as oil, spirits, wood or paper may be stored.


  Z620 Conventional Heat Detector, PS1226.4

Based on advanced thermistor technology, the Z620 series of heat detectors, provides a reliable response to fires in areas where environmental conditions prohibit the use of smoke detection.

Z620-581 is a fixed temperature model, operating at 58oC. It is intended for applications where fluctuations of ambient temperature may be expected for example, over machinery in laundries, or factory locations where industrial processes may cause sharp temperature increases.


  Z630-1 Conventional Optical Smoke Detector, PS1272.1

Designed to provide an early response to a wide range of slow burning, smouldering fires the Z630-1 optical smoke detector, provides reliable sensing for most conventional fire alarm applications. The detectors aesthetic design and proven stability in air movements associated with air conditioning systems, have made it an ideal selection for modern building interiors.

The Z630-1 meets fully the sensitivity requirements of European Standard EN 54 Pt 7 and is approved by several international approval bodies including the Loss Prevention Certification Board (LPCB).


  Z610A-1 Conventional Ionization Smoke Detector - Adjustable Sensitivity, PS1347.2

Designed to provide an early response to fast burning fires, the Z610A-1 ionization detector provides reliable sensing of both visible and invisible products of combustion. The detectors adjustable sensitivity, makes it ideal for areas where smoke particles may be intermittently present.

Three sensitivity levels are site selectable, via jumper switch settings located in the base plate of the unit. This allows detector response to be matched to a range of environmental requirements


  Z610U-2 Conventional Ionization Detector, PS1420.1

Designed to provide an early response to fast burning fires, the Z610U-2 ionization detector features reliable sensing of both visible and invisible products of combustion, for a range of conventional fire alarm applications. The detectors advanced design and proven response make it effective in risk areas where materials such as oil, spirits, wood or paper may be stored.

The Z610U-2 meets fully the sensitivity requirements of UL 268.Featuring an advanced dual chamber, single source design, the detectors chamber arrangement automatically compensates for environmental changes such as atmospheric pressure, humidity and ambient temperature.


  Z610AU-2 Conventional Ionization Smoke Detector - Adjustable Sensitivity, PS1421.1

Designed to provide an early response to fast burning fires, the Z610AU-2 ionization detector provides reliable sensing of both visible and invisible products of combustion. The detectors adjustable sensitivity, makes it ideal for areas where smoke particles may be intermittently present.

Three sensitivity levels are site selectable, via jumper switch settings located in the base plate of the unit. This allows detector response to be matched to a range of environmental requirements.


  Z620U-621-2 Conventional Heat Detector (Fixed Temperature), PS1424.1

Based on advanced thermistor technology, the Z620 series of heat detectors, provides a reliable response to fires in areas where environmental conditions prohibit the use of smoke detection.

The Z620U-621-2 is a fixed temperature model, operating at 135oF (58oC). It is intended for applications where fluctuations of ambient temperature may be expected for example, over machinery in laundries, or factory locations where industrial processes may cause sharp temperature increases.


  Z620U-622-2 Conventional Heat Detector (Rate of Rise), PS1425.1

Based on advanced thermistor technology, the Z620 series of heat detectors, provides a reliable response to fires in areas where environmental conditions prohibit the use of smoke detection.

The Z620U-622-2 has a static alarm threshold of 135oF (58oC) and operates on the rate of rise of its ambient temperature. To increase response time, without compromising reliability, a rate compensation element enables the detector to become more sensitive to higher rates of temperature rise. Applications include general use in areas where smoke detection would be likely to produce false alarms, for example in kitchens and shower room.


  Z630A-1 Conventional Optical Smoke Detector - Adjustable Sensitivity PS1348.2

Designed to provide an early response to slow burning, smouldering fires, the Z630A-1 optical detector provides reliable sensing for most conventional fire alarm applications. The detectors adjustable sensitivity, makes it ideal for areas where smoke particles may be intermittently present.

Three sensitivity levels are site selectable, via jumper switch settings located in the base plate of the unit. This allows detector response to be matched to a range of environmental requirements.


  Z630U-2 Conventional Optical Smoke Detector, PS1422.1

Designed to provide an early response to a wide range of slow burning, smouldering fires the Z630U-2 optical smoke detector, provides reliable sensing for most conventional fire alarm applications. The detectors aesthetic design and proven stability in air movements associated with air conditioning systems, have made it an ideal selection for modern building interiors. The Z630U-2 meets fully the sensitivity requirements of UL 268.

The detector operates on the light scatter principle, making it effective in applications where fires producing large particle smoke can be expected.


  Z630AU-2 Conventional Optical Smoke Detector - Adjustable Sensitivity, PS1423.1

Designed to provide an early response to slow burning, smouldering fires, the Z630AU-2 optical detector provides reliable sensing for most conventional fire alarm applications. The detectors adjustable sensitivity, makes it ideal for areas where smoke particles may be intermittently present.

Three sensitivity levels are site selectable, via jumper switch settings located in the base plate of the unit. This allows detector response to be matched to a range of environmental requirements.

 
© 2007 Dafoos Fire Protection