The ZP785-2 is an
addressable call point providing
a manual means of initiating a fire
alarm on ZP analogue addressable
systems.
Complying with
BS 5839 Part 2 and pr EN 54 Part
11, the ZP785-2 is suitable for
installations meeting the recommendations
of BS 5839 Part 1:1988. The callpoint
is approved by several international
approval bodies, including the loss
Prevention Certification Board (LPCB).
ZP787-2
Addressable Callpoint, PS1250.2
The ZP787-2 is a waterproof
,surface mounting, call point providing
a manual means of initiating a fire
alarm. Rated at IP67, the unit is
designed for outdoor applications
or in systems where the ingress
of water can be expected, for example
where hygiene requirements demand
regular washing or hosing down of
the protected area.
Complying with
BS 5839 Part 2 and pr EN 54 Part
11, the ZP787-2 is suitable for
installations meeting the recommendations
of BS 5839 Part 1:1988. The callpoint
is approved by several international
approval bodies, including the loss
Prevention Certification Board (LPCB).
ZP740
Addressable Line Interface Unit, PS1246.1
Designed to
provide an interface, for associated
systems and equipment, the ZP740
can be configured to accept a variety
of input types.
Switch settings
are provided to select input type.
Once set the ZP740 will accept the
chosen input and on operation, the
control panel will automatically
display a message particular to
that device type.
ZP750-2
Addressable Line Relay Unit, PS1247.2
The ZP750-2
is an addressable relay providing
single pole, volt free, change over
contacts. The unit is intended for
installation adjacent to equipment
to be switched, thereby offering
large savings in installation costs
when compared to long, auxiliary
circuit, wiring runs out from the
control panel.
Located anywhere on
the two core ZP loop the device
is designed for power up or shut
down of building services in fire
conditions, for example the shut
down of heating and ventilating
equipment in order to prevent smoke
spread in occupied areas. The relay
is ideal for the control of associated
system equipment such as door release
circuits, or the emergency shutdown
of high risk services, for instance
gas or oil supply valves in boiler
rooms.
ZP752-2
Addressable Two Way Monitored Output
Unit, PS1252.2
The
ZP752-2 is a loop wired interface
providing two conventional alarm
circuits. It can be programmed to
operate from a single address, a
group or zone of devices or as a
common output, from any trigger
device connected to the system.
Power for the
alarm circuits is supplied either
from an external power supply unit,
or directly from the panels 24 volt
dc supply (via separate wiring).
The ZP752-2 monitors its power supply
and failure of mains, battery or
loss of the 24 volt DC output is
reported to the main control panel
automatically.
ZP760-2
Line Isolator Unit, PS1248.3
Designed to provide
short circuit protection for loop
wiring, ZP760-2 line isolators divide
the loop into monitored sections.
A maximum of 16 isolator units can
be connected along each ZP loop,
which together with isolators at
the beginning and end (internal
to the panel), enable each loop
to be divided into a maximum of
17 monitored sections.
The ZP760-2 is intended
for use on a "Class-A"
return loop wiring configuration.
Either 1 zone or up to 20 detectors
or devices (some standards permit
up to 32) are located between each
pair of loop isolators. In the event
of a short circuit fault the isolators
on either side of the fault will
disconnect the section of cable
between them. Devices outside the
disconnected section will continue
to operate normally.
ZP745
Addressable Miniature Interface Unit,
PS1262.3
Measuring
only 51mm by 55mm the ZP745 miniature
addressable interface is designed
for installation within the enclosures
of control equipment associated
with fire detection systems. The
unit is installed directly onto
the ZP loop wiring, carries a system
address and enables signals from
associated equipment to be interfaced
into the fire alarm system. Input
signals are fully displayed at the
ZP3 control panel and can be programmed
to activate any ZP system output.
By routing loop wiring
to pick up interfaces located inside
control equipment cabinets, signals
are accepted directly onto the ZP
fire alarm communications loop,
greatly increasing system integrity
by eliminating the need for spur
wiring between associated equipment
terminals and the fire alarm interface.
ZP755HAV
Addressable Sounder Beacon, PS1670.1
Across the
world disability legislation increasingly
requires visual alarm signals to
be employed to ensure equal response
from people with hearing impairment.
The ZP755HAV is perfectly suited
for this application and indeed
any involving high levels of background
noise.
It provides both audible
and visual warnings from a single,
addressable, loop wired unit. Featuring
an identical profile to the ZP755
HA horn sounder, the ZP755HAV can
minimise the number of installation
points required throughout a building,
significantly lowering both the
capital value of equipment and the
loop wiring costs of the completed
system.
ZP755HA/HB
Addressable Horn Sounders, PS1264.2
Developed
for general area coverage, ZP755
HA and ZP755 HB have sound distribution
characteristics suitable for matching
the requirements of most open areas.
ZP755 HA is
designed with dual front and rear
sound paths, providing an 'all around'
sound output - ideal for open area
coverage. Whilst the ZP755 HB features
a 'forward directional' output,
making it effective in corridors,
passageways and on escape routes.
ZP755B Addressable Sensor Base Sounder,
PS1304.2
The
ZP755B is an addressable, sensor
base sounder, designed for use on
ZP3 analogue addressable fire detection
and alarm systems. It is especially
cost effective in residential buildings,
where the recommendations of BS
5839 Pt:1 1988 of 75 dBA sound output
at bed heads, usually means the
provision of a sounder in each bedroom.
Sharing an address
with its sensor - the ZP755B is
installed directly onto the ZP wiring
loop - offering full ZP3 analogue
addressable features on a single
pair of wires. Installation costs
are greatly reduced, whilst system
integrity, sounder options and programmed
alarm organisation are significantly
increased.
ZP755R
Addressable Room Sounder, PS1305.2
The ZP755R
is an addressable, sounder, designed
for use on ZP3 analogue addressable
fire detection and alarm systems.
Developed for applications in individual
rooms, sleeping accommodation or
small compartments where it is impractical
or unnecessary for the sounder and
sensor to be combined.
Installed directly
onto the ZP wiring loop - the ZP755R
enables the system designer to offer
a complete ZP3 analogue addressable
system on a single pair of wires.
Installation costs are greatly reduced,
whilst system integrity, sounder
options and programmed alarm organisation
are significantly increased.
ZP755W
Addressable Weatherproof Sounder,
PS1306.2
The
ZP755W is an addressable, weatherproof
sounder, designed for use on ZP
analogue addressable fire detection
and alarm systems. The sounder has
been developed for outdoor applications,
or for use in areas where the ingress
of water can be expected, for example
where hygiene requirements demand
regular washing or hosing down of
the protected area.
Installed directly
onto and powered by the ZP wiring
loop, the ZP755 range enables the
system designer to offer a complete
ZP analogue addressable system on
a single pair of wires. Installation
costs are greatly reduced, whilst
system integrity, sounder options
and programmed alarm organisation
are significantly increased.
ZP570-2
Addressable Zone Interface Unit, PS1251.2
Analogue addressable
systems are rarely installed in
a single phase. On larger sites
primary buildings and main risk
areas are often upgraded in an initial
phase with others refurbished in
subsequent stages. The ZP570-2 zonal
unit enables existing conventional
zones to be interfaced to an analogue
system, allowing all areas of the
site to be controlled by the ZP
analogue panel immediately, until
future events or budgets allow full
analogue integration.
Any new or existing
zone of conventional devices can
be connected to the interface, which
can be installed anywhere on the
ZP analogue loop. Each interface
is assigned a unique address and
monitors its zone for fire and fault
conditions. Zonal status is reported
to the ZP control panel, every 2
seconds.
A45E-2
Addressable Interface Module, PS1762.1
The
A45E-2 addressable interface is
designed for installation within
the enclosures of equipment associated
with fire detection systems. The
unit is installed directly onto
the ZP loop wiring, carries a system
address and enables signals from
associated equipment to be interfaced
into the fire alarm system. Input
signals are fully displayed at the
ZP3 control panel and can be programmed
to activate any ZP system output.
A50E-2
Addressable Line Relay Module, PS1761.1
The
A50E-2 is an addressable relay providing
single pole, volt free, change over
contacts. The unit is intended for
installation within the equipment
to be switched, thereby offering
savings in installation costs when
compared to long, auxiliary circuit,
wiring runs out from the control
panel.
A60E-2 Line Isolator Unit, PS1766.1
The A60E line
isolator provides short circuit
protection, for analogue addressable
loop wiring. Isolators are connected
at intervals along the length of
the loop, dividing the wiring into
a series of separate monitored sections.