The ZP3AB-MIP8 is
one of a series of additional, auxiliary
boards designed to extend the ZP3
panel standard range of input/output
facilities. Boards are modular in
design, and are mounted inside the
ZP3 panel enclosure, by means of
a ZP3-AC1 auxiliary chassis.
Up to three
boards can be fitted into a ZP3
panel. They may be all of a single
type, or any combination from the
I/O module range. Further boards
can be added to a system, accommodated
in a remote control cabinet, usually
located alongside the ZP3 panel.
Various sized cabinets are available,
designed to match the control panel
enclosure.
The
ZP3AB-MA8 is one of a series of
additional, auxiliary boards designed
to extend the ZP3 panel standard
range of input/output facilities.
Boards are modular in design, and
are mounted inside the ZP3 panel
enclosure, by means of a ZP3-AC1
auxiliary chassis.
Up to three
boards can be fitted into a ZP3
panel. They may be all of a single
type, or any combination from the
I/O module range. The addition of
auxiliary boards can increase the
panel outputs to a maximum of 72
all housed within the ZP3 enclosure.
The
ZP3AB-NET1 enables ZP3 control panels
to be connected together to form
networks. The interface card is
attached directly onto the ZP3 main
control board inside the panel enclosure.
Up to 32 standalone control panels
can be linked to form the ZP network
allowing the integration of over
16,000 system devices.
Networks can
be designed as peer to peer systems
where all control panels are connected
to form a single co-ordinated fire
detection and alarm system. Each
panel controls its own devices and
displays its own systems information,
but is capable of cross panel cause
and effect operation. The ZP3AB-NET1
network board also enables hierarchical
networks to be easily configured,
where one or more control panels
can be assigned as masters displaying
complete system status.
ZP3AB-OP24
24 Way Programmable Open Collector,
PS1297.2
The
ZP3AB-OP24 is one of a series of
additional, auxiliary boards designed
to extend the ZP3 panel standard
range of input/output facilities.
Boards are modular in design, and
are mounted inside the ZP3 panel
enclosure, by means of a ZP3-AC1
auxiliary chassis.
Up to three
boards can be fitted into a ZP3
panel. They may be all of a single
type, or any combination from the
I/O module range. The addition of
auxiliary boards can increase the
panel outputs to a maximum of 72
all housed within the ZP3 enclosure.
ZP3AB-RL8
8 Way Programmable Relay Output Board,
PS1298.2
The
ZP3AB-RL8 is one of a series of
additional, auxiliary boards designed
to extend the ZP3 panel standard
range of input/output facilities.
Boards are modular in design, and
are mounted inside the ZP3 panel
enclosure, by means of a ZP3-AC1
auxiliary chassis.
Up to three
boards can be fitted into a ZP3
panel. They may be all of a single
type, or any combination from the
I/O module range. The addition of
auxiliary boards can increase the
panel outputs to a maximum of 72
all housed within the ZP3 enclosure.
ZP3AB-RS232
Serial Communications Optional Facility
Card, PS1299.2
The
ZP3AB-RS232 is a serial communications
interface which can be attached
directly onto the ZP3 main control
board, inside the panel enclosure.
The board is used to connect the
fire alarm panel to external devices
for example a desk top printer,
or to associated equipment such
as graphics displays, pocket paging
and building management systems.
Serial communication
between the fire alarm panel and
external device operates by RS 232
protocol, over a 5 wire screened
connection. The ZP3AB-RS232 board
is defined in the ZP3 fire alarm
panel menu as Port 1 and a range
of software protocols can be selected
to match the requirements of the
external communicating system or
device.
ZP3AB-SCB-D
Serial Display Unit Interface, PS1309.3
The ZP3AB-SCB
is a serial control bus driver,
which can be attached directly onto
the ZP3 main control board inside
the panel enclosure. It provides
the means to connect and operate
from 1 to 32 remote display units
(ZP3-RDUB1) and or remote control
units (ZP3AB-SCB-R), enabling repeat
indication and system control, at
locations remote from the main panel
position.
Serial communication
between the main panel and remote
display units operates by RS 485
protocol, over twisted screened
pair wiring.
ZP3AB-NLM
Network Loop Module, PS0927.1
The ZP3AB-NLM
network loop module enables individual
ZP3 control panels to be connected
in a peer to peer, secure loop network.
ZP3-PR1
Optional Printer Kit, PS1300.2
The ZP3-PR1 is a 24
character dot matrix printer, which
can be fitted to the front door
of the ZP3 control panel. The kit
comprises a printer module, printed
circuit driver board and the necessary
mounting hardware to fit the unit.
The printer
is software controlled with operating
parameters simply configured, in
the fire alarm system set up programme,
to respond to a comprehensive range
of system events.
ZP5-GCU2
Addressable Gas Unit, PS1464.2
The Ziton ZP Gas Control
Unit is designed to connect to a
ZP fire detection system. Each Gas
Control Unit controls one Halon
1301/1211 or Carbon Dioxide CO2
gas fire extinguishing sys-tem.
The ZP fire control panel provides
secure "Co-incidence Connection"
control of the gas extinguishing
system.
It is field
programmable, with cross-mapped
inputs being selected from various
ZP line devices or zones. Functions
such as automatic gas release delay,
selection of delay/no-delay for
manual gas release, and output relay
control are fully configurable.
ZP5-GCU2S
Gas Control Status Unit, PS1465.2
The Ziton ZP5-GCU2S
Gas Status Unit is designed to connect
to a ZP5-GCU2 Gas Control Unit.
The Gas Control unit in turn connects
to a Ziton ZP fire detection system,
and controls a Halon 1301/1211 or
Carbon Dioxide CO2 gas fire extinguishing
system.
The Gas Status Unit
has key switches to enable remote
control of the Gas Control Unit
for auto-matic or manual selection,
as well as lock-off for maintenance.
Other controls are manual gas release,
and an alarm silence push button.
Indi-cators mimic those on the Gas
Control Unit for automatic, manual,
locked-off, gas discharged and reset
status.
ZP5-GCU2R
Gas Control Repeater Unit, PS1466.2
The Ziton ZP5-GCU2R
Gas Repeater Unit is designed to
connect to a ZP5-GCU2 Gas Control
Unit. The Gas Control unit in turn
connects to a Ziton ZP fire detection
system, and controls a Halon 1301/1211
or Carbon Dioxide CO2 gas fire extinguishing
system.
The Gas Repeater
Unit has indicators which mimic
those on the Gas Control Unit for
auto-matic, manual, locked-off,
gas discharged and reset status.
ZD
Indicator Modules, PS1692.1
The ZD range
of control and indicating modules
provides, in conjunction with the
CPU controls and display, operator
interfaces for any configuration
of Ziton analogue addressable or
conventional, Modula control or
repeat panel.
TZR8
Modula 8 Way Relay Card, PS1695.1
Providing eight
volt free relays, each of which
can be independently configured
as normally open or normally closed,
the ZR8 occupies a single card space
on the chassis rail.
The
ADC card provides a single loop
circuit for connecting up to 127
analogue addressable devices to
the ZM2 or ZM8 control panels. In
addition two conventional alarm
circuits for polarised electronic
sounders, bells and visual indicators
can also be connected to each ADC
card.